Compliance Results Non-Compliant
Rule Submitted Required Reference
Front Setback
Front setback 5.0m meets requirement of 4.0m
4.0 meters Table 17, G.O.Ms.No.119
Rear Setback
Rear setback 3.0m meets requirement of 2.5m
2.5 meters Table 17, G.O.Ms.No.119
Side 1 Setback
Side 1 setback 3.0m meets requirement of 2.0m
2.0 meters Table 17, G.O.Ms.No.119
Side 2 Setback
Side 2 setback 3.0m meets requirement of 2.0m
2.0 meters Table 17, G.O.Ms.No.119
Parking Requirement
Parking 25.0% is less than required 40%
Add 180.0 sq.m parking area or apply for parking fee waiver
40 % of built-up Table 11, G.O.Ms.No.119
Habitable Room Area
Room area 12.0 sq.m meets minimum 9.5 sq.m
9.5 sq.m Table 5, G.O.Ms.No.119
Habitable Room Width
Room width 3.0m meets minimum 2.4m
2.4 meters Table 5, G.O.Ms.No.119
Kitchen Area
Kitchen area 6.0 sq.m meets minimum 4.5 sq.m
4.5 sq.m Table 5, G.O.Ms.No.119
Floor Area Ratio
FAR 2.00 exceeds maximum permissible 1.75
Reduce built-up area by 150.0 sq.m
1.75 ratio Chapter VII, G.O.Ms.No.119
Ground Coverage
Ground coverage 66.7% is within limit of 70%
70 % Chapter VII, G.O.Ms.No.119
Rain Water Harvesting
Rain water harvesting provision included
1 provision Chapter XI-1, Rule 152
Fire Department NOC
Fire NOC not required for this building
0 clearance Chapter VI, G.O.Ms.No.119
Building Details
Building Type
Residential
Plot Area
600.0 sq.m
Number of Floors
3
Building Height
12.0 m
Total Built-up Area
1200.0 sq.m
Building Classification
Non-High-Rise

Setbacks Provided

Front Setback
5 m
Rear Setback
3 m
Side 1 Setback
3 m
Side 2 Setback
3 m

Provisions

Rain Water Harvesting
Yes
Solar Panels
Yes
Sewage Treatment Plant
No